Comparative Diagnostic Performance and Clinical Effectiveness of Intraoperative Quality Control Modalities in Coronary Revascularization: a Systematic Review and Aggregate Comparative Analysis of Real-World Evidence

Alimzhan Yelzhassov 1 2 * , Almas Tolegenuly 1, Aidos Yerpashov 1, Sergey Leontyev 3, Assel Chinybayeva 4, Ayan Abdrakhmanov 4, Anastassiya Ganina 1, Adil Abdinurov 1
More Detail
1 Department of Cardiac Surgery, National Scientific Medical Center, Astana, Kazakhstan
2 PhD Program, Astana Medical University, Astana, Kazakhstan
3 Department of Cardiac Surgery, Leipzig Heart Center, Leipzig, Germany
4 Heart Rhythm Scientific Research Institute, Astana Medical University, Astana, Kazakhstan
* Corresponding Author
J CLIN MED KAZ, Volume 23, Issue 5, pp. 94-102. https://doi.org/10.23950/jcmk/19615
OPEN ACCESS 301 Views 114 Downloads
Download Full Text (PDF)
Author Contributions: Conceptualization, A.Yel. and A.T. (Almas Tolegenuly); methodology, A.Yel. and A.T.; validation, A.T.; formal analysis, A.Yel. and A.Yer.; investigation, A.Yel. ; resources, A.T.; data curation, A.Yel. ; writing – original draft preparation, A.Yel. A.A. ; writing – review and editing, A.Yel. and A.C; visualization, A.Yel.; supervision, A.T. and S.L.; project administration, A.T. and A.Abdr.; funding 
acquisition – not applicable. All authors have read and agreed to the published version of the manuscript.

Data availability statement: All quantitative data extracted and analyzed during this study, as well as the RStudio statistical scripts, are included within the published manuscript and its supplementary information files.

Artificial Intelligence (AI) Disclosure Statement: During manuscript preparation, artificial intelligence technologies were limited strictly to linguistic editing and proofreading. AI systems were not applied for data analysis, statistical modeling, or creating scientific statements. All text and findings were critically evaluated and verified by the authors.

ABSTRACT

Intraoperative graft assessment during coronary artery bypass grafting (CABG) aims to identify technical anastomotic defects before chest closure. Transit-time flow measurement (TTFM) and indocyanine green (ICG) fluorescence imaging represent complementary intraoperative assessment modalities, yet their comparative diagnostic performance against angiographic reference standards remains incompletely defined.
PubMed, Scopus, Web of Science Core Collection, and CENTRAL were searched from January 2000 to February 2026 using terms for CABG, ICG, and TTFM; duplicate screening yielded κ = 0.86–0.91. Eligible studies evaluated ICG and/or TTFM against invasive coronary angiography or computed tomography coronary angiography. Methodological quality was appraised using QUADAS-2 for diagnostic cohorts and the Newcastle-Ottawa Scale (NOS) for clinical-utility cohorts. Because only three directly comparable cohorts provided sufficiently reliable paired 2×2 data, formal bivariate random-effects meta-analysis was not performed. Verified 2×2 contingency data were summarised descriptively with exact Clopper–Pearson 95% confidence intervals. Clinical-utility evidence was synthesised narratively.
Eighteen unique primary clinical studies were included. Three studies (Desai et al., 2006; Yamamoto et al., 2015; Hatada et al., 2011), comprising 293 paired bypass grafts, provided directly comparable quantitative evidence. ICG demonstrated an aggregate descriptive sensitivity of 76.0% (95% CI, 54.9%–90.6%) and specificity of 99.3% (95% CI, 97.3%–99.9%). TTFM/flowmetry demonstrated aggregate sensitivity of 24.0% (95% CI, 9.4%–45.1%) and specificity of 96.3% (95% CI, 93.2%–98.2%). Formal between-modality P values were not calculated. The aggregate flowmetry estimate includes one cohort using experimental FFT-based waveform analysis (Hatada et al., 2011) and should be interpreted with caution. NOS assessment of six Tier 3 clinical-utility studies yielded scores of 5–9/9; no study provided a complete two-arm comparison with non-zero revision events in both arms, precluding pooled effect estimation.
ICG fluorescence imaging showed higher descriptive sensitivity than TTFM/flowmetry for detecting structural graft abnormalities. A complementary approach combining quantitative flow assessment with selective fluorescence imaging may be considered in appropriately selected situations. Prospective multicenter studies are required before definitive recommendations can be made.

CITATION

Yelzhassov A, Tolegenuly A, Yerpashov A, Leontyev S, Chinybayeva A, Abdrakhmanov A, et al. Comparative Diagnostic Performance and Clinical Effectiveness of Intraoperative Quality Control Modalities in Coronary Revascularization: a Systematic Review and Aggregate Comparative Analysis of Real-World Evidence. J CLIN MED KAZ. 2026;23(5):94-102. https://doi.org/10.23950/jcmk/19615

REFERENCES

  • Neumann FJ, Sousa-Uva M, Ahlsson A, Alfonso F, Banning AP, Benedetto U, Byrne RA, Collet JP, Falk V, Head SJ, Jüni P, Kastrati A, Koller A, Kristensen SD, Niebauer J, Richter DJ, Seferovic PM, Sibbing D, Stefanini GG, Windecker S, Yadav R, Zembala MO. 2018 ESC/EACTS Guidelines on myocardial revascularization. Eur Heart J. 2019; 40 (2): 87–165. https://doi.org/10.1093/eurheartj/ehy394 .
  • Gaudino M, Hameed I, Robinson NB, Ruan Y, Demetres M, Rahouma M, Morsi M, Spadaccio C, Bhatt DL, Fremes SE, Girardi LN. Aortocoronary bypass grafts. Circulation. 2023; 148 (18): 1305–1315. https://doi.org/10.1161/CIRCULATIONAHA.123.064090 .
  • Baumgarten H, Squiers JJ, DiMaio JM, Mack MJ, Jessen ME. Post-CABG myocardial infarction outcomes. J Invasive Cardiol. 2023; 35: E161–E168. https://doi.org/10.25270/jic/21.00376 .
  • Akhrass R, Bakaeen FG. Intraoperative graft patency validation: friend or foe? JTCVS Tech. 2021; 7: 131–137. https://doi.org/10.1016/j.xjtc.2020.12.040 .
  • Leong DK, Ashok V, Nishkantha A, Shan YH, Sim EK. Transit-time flow measurement is essential in coronary artery bypass grafting. Ann Thorac Surg. 2005; 79 (3): 854–857. https://doi.org/10.1016/j.athoracsur.2004.06.010 .
  • Niclauss L. Techniques and standards in intraoperative graft verification by transit time flow measurement after coronary artery bypass graft surgery: a critical review. Eur J Cardiothorac Surg. 2017; 51 (1): 26–33. https://doi.org/10.1093/ejcts/ezw203 .
  • Thuijs DJFM, Bekker MWA, Taggart DP, Kappetein AP, Kieser TM, Wendt D, Di Giammarco G, Trachiotis GD, Puskas JD, Head SJ. Improving coronary artery bypass grafting: a systematic review and meta-analysis on the impact of adopting transit-time flow measurement. Eur J Cardiothorac Surg. 2019; 56 (4): 654–663. https://doi.org/10.1093/ejcts/ezz075 .
  • Di Giammarco G, Canosa C, Foschi M, Rabozzi R, Marinelli D, Masuyama S, Ibrahim BM, Ranalletta RA, Penco M, Di Mauro M. Intraoperative graft verification in coronary surgery: increased diagnostic accuracy adding high-resolution epicardial ultrasonography to transit-time flow measurement. Eur J Cardiothorac Surg. 2014; 45 (4): e41–e45. https://doi.org/10.1093/ejcts/ezt543 .
  • Desai ND, Miwa S, Kodama D, Koyama T, Cohen G, Pelletier MP, Cohen EA, Christakis GT, Goldman BS, Fremes SE. A randomized comparison of intraoperative indocyanine green angiography and transit-time flow measurement to detect technical errors in coronary bypass grafts. J Thorac Cardiovasc Surg. 2006; 132 (3): 585–594. https://doi.org/10.1016/j.jtcvs.2005.09.061 .
  • Balacumaraswami L, Abu-Omar Y, Choudhary B, Pigott D, Taggart DP. A comparison of transit-time flowmetry and intraoperative fluorescence imaging for assessing coronary artery bypass graft patency. J Thorac Cardiovasc Surg. 2005; 130 (2): 315–320. https://doi.org/10.1016/j.jtcvs.2004.11.033 .
  • Waseda K, Ako J, Hasegawa T, Shimada Y, Ikeno F, Ishikawa T, Tsujino I, Nishimura T, Miyazawa A, Bia D, Bers DM, Bhatt DL, Cooke JP, Kaneda H, Honda Y, Fitzgerald PJ. Intraoperative fluorescence imaging system for on-site assessment of off-pump coronary artery bypass graft. JACC Cardiovasc Imaging. 2009; 2 (5): 604–612. https://doi.org/10.1016/j.jcmg.2008.12.028 .
  • Detter C, Wipper S, Russ D, Iffland A, Burdorf L, Thein E, Reichenspurner H, Reichart B. Fluorescent cardiac imaging: a novel intraoperative method for quantitative assessment of myocardial perfusion during graded coronary artery stenosis. Circulation. 2007; 116 (9): 1007–1014. https://doi.org/10.1161/CIRCULATIONAHA.106.655936 .
  • Spadaccio C, Nenna A, Corrado D, Glenn C, Panza A, Vester R, Nappi F, Chello M, Gaudino M. Use of indocyanine green (ICG) to assess myocardial perfusion and territorial distribution of vein grafts implanted on coronary arteries in an ex vivo porcine model. Rev Cardiovasc Med. 2025; 26: 25778. https://doi.org/10.31083/RCM25778 .
  • Khalpey Z, Kumar U, Khalpey Z, Phillips T, Khaliel F. Indocyanine green fluorescence imaging for accurate detection of an intramural coronary artery during robotic coronary artery bypass grafting. JTCVS Tech. 2025; 30: 94–97. https://doi.org/10.1016/j.xjtc.2025.01.018 .
  • Kuroyanagi S, Asai T, Suzuki T. Intraoperative fluorescence imaging after transit-time flow measurement during coronary artery bypass grafting. Innovations. 2012; 7 (6): 435–440. https://doi.org/10.1177/155698451200700611 .
  • Hatada A, Okamura Y, Kaneko M, Hisaoka T, Yamamoto S, Hiramatsu T, Nishimura Y. Comparison of the waveforms of transit-time flowmetry and intraoperative fluorescence imaging for assessing coronary artery bypass graft patency. Gen Thorac Cardiovasc Surg. 2011; 59 (1): 14–18. https://doi.org/10.1007/s11748-010-0611-1 .
  • Usta H, Çolak A, Kaya U, Ceviz M, Jalalzai I, Yıldız A. Comparison of the effects of indocyanine fluorescence imaging and transit-time flow measurement on early outcomes in coronary artery bypass grafting. Turk Gogus Kalp Damar Cerrahisi Derg. 2025; 33 (4): 432–441. https://doi.org/10.5606/tgkdc.dergisi.2025.27779 .
  • Reuthebuch O, Häussler A, Genoni M, Tavakoli R, Odavic D, Kadner A, Turina M. Novadaq SPY: intraoperative quality assessment in off-pump coronary artery bypass grafting. Chest. 2004; 125 (2): 418–424. https://doi.org/10.1378/chest.125.2.418 .
  • Balacumaraswami L, Taggart DP. Digital tools to facilitate intraoperative coronary artery bypass graft patency assessment. Semin Thorac Cardiovasc Surg. 2004; 16 (3): 266–271. https://doi.org/10.1053/j.semtcvs.2004.08.014 .
  • Taggart DP, Choudhary BP, Anastasiadis K, Abu-Omar Y, Balacumaraswami L, Pigott D. Preliminary experience with a novel intraoperative fluorescence imaging technique to evaluate the patency of bypass grafts in total arterial revascularization. Ann Thorac Surg. 2003; 75 (3): 870–873. https://doi.org/10.1016/s0003-4975(02)04701-4 .
  • Handa T, Katare RG, Sasaguri S, Sato T. Preliminary experience for the evaluation of the intraoperative graft patency with real color charge-coupled device camera system. Interact Cardiovasc Thorac Surg. 2009; 9 (2): 150–154. https://doi.org/10.1510/icvts.2008.201418 .
  • Yamamoto M, Orihashi K, Nishimori H, Handa T, Kondo N, Fukutomi T, Sato T. Efficacy of intraoperative HyperEye Medical System angiography for coronary artery bypass grafting. Surg Today. 2015; 45 (11): 1413–1419. https://doi.org/10.1007/s00595-014-1087-0 .
  • Tokuda Y, Song MH, Ueda Y, Usui A, Akita T. Predicting early coronary artery bypass graft failure by intraoperative transit time flow measurement. Ann Thorac Surg. 2007; 84 (6): 1928–1933. https://doi.org/10.1016/j.athoracsur.2007.07.032 .
  • Walker PF, Daniel WG, Moss E, Thourani V, Kilgo P, Liberman H, Devireddy C, Guyton R, Puskas J, Halkos M. The accuracy of transit time flow measurement in predicting graft patency after coronary artery bypass grafting. Innovations. 2013; 8 (6): 416–421. https://doi.org/10.1097/IMI.0000000000000028 .
  • Jokinen JJ, Werkkala K, Vainikka T, Peräkylä T, Simpanen J, Ihlberg L. Clinical value of intra-operative transit-time flow measurement for coronary artery bypass grafting: a prospective angiography-controlled study. Eur J Cardiothorac Surg. 2011; 39 (6): 918–923. https://doi.org/10.1016/j.ejcts.2010.10.006 .
  • Lehnert P, Møller CH, Damgaard S, Gerds T, Steinbrüchel D. Transit-time flow measurement as a predictor of coronary bypass graft failure at one year angiographic follow-up. J Card Surg. 2015; 30 (1): 47–52. https://doi.org/10.1111/jocs.12461 .
  • Taggart DP, Thuijs DJFM, Di Giammarco G, Altena S, Puskas JD, Kieser TM. Intraoperative transit-time flow measurement and high-frequency ultrasound assessment in coronary artery bypass grafting. J Thorac Cardiovasc Surg. 2020; 159 (4): 1283–1287. https://doi.org/10.1016/j.jtcvs.2019.05.087.
  • Hol PK, Lingaas PS, Lundblad R, Rein KA, Vatne K, Smith HJ, Nitter-Hauge S, Fosse E. Intraoperative angiography leads to graft revision in coronary artery bypass surgery. Ann Thorac Surg. 2004; 78 (2): 502–505. https://doi.org/10.1016/j.athoracsur.2004.03.004 .
  • Becit N, Erkut B, Ceviz M, Ünlü Y, Colak A, Koçak H. The impact of intraoperative transit time flow measurement on the results of on-pump coronary surgery. Eur J Cardiothorac Surg. 2007; 32 (2): 313–318. https://doi.org/10.1016/j.ejcts.2007.04.037
  • FitzGibbon GM, Kafka HP, Leach AJ, Keon WJ, Hooper GD, Burton JR. Coronary bypass graft fate and patient outcome: angiographic follow-up of 5,065 grafts related to survival and reoperation in 1,388 patients during 25 years. J Am Coll Cardiol. 1996; 28 (3): 616–626. https://doi.org/10.1016/0735-1097(96)00206-9 .
  • Magee MJ, Alexander JH, Hafley GE, Ferguson TB, Gibson CM, Harrington RA, Peterson ED, Califf RM, Kouchoukos NT, Herbert MA, Mack MJ. Coronary artery bypass graft failure after on-pump and off-pump coronary artery bypass: findings from PREVENT IV. Ann Thorac Surg. 2008; 85 (2): 494–500. https://doi.org/10.1016/j.athoracsur.2007.10.008 .
  • Hattler BC, Messenger JC, Shroyer AL, Collins JF, Haugen SJ, Garcia JA, Baltz JH, Cleveland JC, Novitzky D, Grover FL. Off-pump coronary artery bypass surgery is associated with worse arterial and saphenous vein graft patency and less effective revascularization: results from the Veterans Affairs Randomized On/Off Bypass (ROOBY) trial. Circulation. 2012; 125 (23): 2827–2835. https://doi.org/10.1161/CIRCULATIONAHA.111.069260 .
  • Mohr FW, Morice MC, Kappetein AP, Feldman T, Ståhle E, Colombo A, Mack MJ, Holmes DR, Morel MA, Van Dyck N, Houle VM, Dawkins KD, Serruys PW. Coronary artery bypass graft surgery versus percutaneous coronary intervention in patients with three-vessel disease and left main coronary disease: 5-year follow-up of the randomised, clinical SYNTAX trial. Lancet. 2013; 381 (9863): 329–338. https://doi.org/10.1016/S0140-6736(13)60141-5 .
  • Sosa MP, McNicholas DG, Bebla AB, Emont S, Cao Z, Lipkin C, Rosenblum JM, Brown JM. Ninety-day all-cause emergency room use among CABG patients associated with near-infrared fluorescence imaging. Ann Med Surg. 2023; 85 (2): 153–160. https://doi.org/10.1097/MS9.0000000000000206 .
  • Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD, Shamseer L, Tetzlaff JM, Akl EA, Brennan SE, Chou R, Glanville J, Grimshaw JM, Hróbjartsson A, Lalu MM, Li T, Loder EW, Mayo-Wilson E, McDonald S, Moher D. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ. 2021; 372: n71. https://doi.org/10.1136/bmj.n71 .
  • Whiting PF, Rutjes AW, Westwood ME, Mallett S, Deeks JJ, Reitsma JB, Leeflang MM, Sterne JA, Bossuyt PM. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med. 2011; 155 (8): 529–536. https://doi.org/10.7326/0003-4819-155-8-201110180-00009 .
  • Sterne JA, Hernán MA, Reeves BC, Savović J, Berkman ND, Viswanathan M, Henry D, Altman DG, Ansari MT, Boutron I, Carpenter JR, Chan AW, Churchill R, Deeks JJ, Hróbjartsson A, Higgins JPT. ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions. BMJ. 2016; 355: i4919. https://doi.org/10.1136/bmj.i4919 .
  • Reitsma JB, Glas AS, Rutjes AW, Scholten RJ, Bossuyt PM, Zwinderman AH. Bivariate analysis of sensitivity and specificity produces informative summary measures in diagnostic reviews. J Clin Epidemiol. 2005; 58 (10): 982–990. https://doi.org/10.1016/j.jclinepi.2005.02.022.